AmScope B120

AmScope B120 Siedentopf Binocular Compound Microscope User Manual

Model: B120

1. Pengenalan dan Lebihview

The AmScope B120 Siedentopf Binocular Compound Microscope is designed for high-magnification biological and educational applications. It features a Siedentopf binocular head for comfortable viewing, a forward-facing nosepiece with four DIN achromatic objectives, Brightfield LED illumination, and a double-layer mechanical stage for precise specimen manipulation.

This microscope provides clear, color-corrected magnified images, making it suitable for detailed inspection and dissection of specimens where two-dimensional images are desired.

AmScope B120 Binocular Compound Microscope

Figure 1: The AmScope B120 Siedentopf Binocular Compound Microscope, showcasing its main components including the binocular head, objective lenses, and mechanical stage.

2. Apa Dalam Kotak

Upon unpacking, please verify that all the following components are present:

  • AmScope B120 microscope with double-layer mechanical stage
  • (4) DIN Standard Objectives: 4x, 10x, 40xS (spring-loaded), and 100xS (spring-loaded, oil immersion)
  • 10x widefield eyepieces, one pair
  • Color filter, blue
  • Immersion oil, one bottle
  • Penutup habuk
  • Arahan (manual ini)

3. Panduan Persediaan

  1. Membongkar: Carefully remove all components from the packaging. Place the microscope body on a stable, level surface.
  2. Attaching the Head: Loosen the head locking screw on the microscope body. Gently insert the Siedentopf binocular head into the top opening of the microscope body. Tighten the locking screw to secure the head.
  3. Memasukkan kanta mata: Insert the two 10x widefield eyepieces into the eyepiece tubes on the binocular head.
  4. Kuasa Penyambung: Connect the power cord to the microscope's power input and then to a standard 110V or 220V AC outlet. Ensure the power switch is in the "Off" position before connecting.
  5. Pelarasan Awal:
    • Inter-pupillary Distance: While looking through the eyepieces, adjust the distance between the two eyepiece tubes until you see a single, clear circular field of view. The inter-pupillary adjustment range is 53 to 77mm.
    • Pelarasan Dioptrik: If one eye is stronger than the other, use the diopter adjustment ring on one of the eyepiece tubes (usually the left one) to compensate. Focus on a specimen with your non-diopter eye first, then adjust the diopter ring for the other eye until both eyes see a sharp image.
sebelah view of AmScope B120 microscope

Rajah 2: Sisi view of the AmScope B120, showing the main body and the position for attaching the binocular head.

4. Arahan Operasi

4.1 Menghidupkan dan Mematikan

Locate the power switch, usually on the side or back of the microscope base. Flip the switch to the "On" position to activate the LED illumination. Flip it to "Off" when not in use.

4.2 Meletakkan Spesimen

  1. Rotate the nosepiece to select the lowest power objective (4x).
  2. Turunkan s mekanikaltage using the coarse focus knob to create enough space.
  3. Place your prepared slide onto the mechanical stage, mengamankannya dengan stage klip.
  4. Use the X-Y axis stage manipulation knobs to center the specimen directly under the objective lens.
Person using AmScope B120 microscope

Figure 3: A user observing a specimen through the AmScope B120 microscope, demonstrating proper posture and handling.

4.3 Memberi tumpuan

  • Fokus Kasar: While looking through the eyepieces, slowly raise the stage using the coarse focus knob until the specimen comes into approximate focus.
  • Fokus Halus: Once the image is roughly focused, use the fine focus knob for precise adjustments to achieve a sharp, clear image.
  • Menukar Objektif: To increase magnification, rotate the nosepiece to the next objective (e.g., from 4x to 10x). The microscope is parfocal, meaning the image should remain largely in focus, requiring only minor adjustments with the fine focus knob.
  • Note: The 40xS and 100xS objectives are spring-loaded to prevent damage to the slide or objective if they accidentally contact.

4.4 Melaraskan Pencahayaan

  • Kawalan Kecerahan LED: Use the dimmer knob (if present) on the microscope base to adjust the intensity of the LED light source.
  • Abbe Condenser: The 1.25 NA Abbe condenser is located beneath the stage. Use the condenser adjustment knob to raise or lower the condenser, controlling the light path and optimizing illumination for different objectives.
  • Diafragma Iris: The iris diaphragm is located within the Abbe condenser. Adjust its lever to control the amount of light illuminating the specimen and to improve contrast. Generally, for higher magnification, you may need to open the diaphragm more.
Atas view of AmScope B120 microscope objectives

Rajah 4: Atas view of the objective lenses and mechanical stage, illustrating the components involved in specimen placement and magnification.

4.5 Using the 100xS Oil Immersion Objective

The 100xS objective requires immersion oil for optimal resolution. Follow these steps:

  1. Focus on your specimen using the 40xS objective.
  2. Rotate the nosepiece halfway between the 40xS and 100xS objectives.
  3. Place a small drop of immersion oil directly onto the center of the illuminated area of the slide.
  4. Carefully rotate the 100xS objective into place, ensuring it makes contact with the oil drop. The spring-loaded mechanism will prevent excessive pressure.
  5. Use only the fine focus knob to bring the image into sharp focus.
  6. After use, always clean the 100xS objective and the slide thoroughly with lens paper and a suitable lens cleaning solution to remove all oil residue.

5. Penyelenggaraan

  • Kanta Pembersihan: Use only specialized lens paper and lens cleaning solution for optical components. Gently wipe the lenses in a circular motion. Avoid touching lenses with bare fingers.
  • Pembersihan Badan: Lap badan mikroskop dengan kain lembut,amp kain. Elakkan menggunakan bahan kimia yang keras atau pembersih yang kasar.
  • Storan: When not in use, cover the microscope with the provided dust cover to protect it from dust and debris. Store in a cool, dry place away from direct sunlight and extreme temperatures.
  • Oil Immersion Care: Always clean the 100xS objective immediately after use to prevent oil from drying on the lens.
  • Moving the Microscope: Always carry the microscope by holding the arm with one hand and supporting the base with the other.

6. Penyelesaian masalah

MasalahKemungkinan PuncaPenyelesaian
Tiada pencahayaanPower cord not connected; Power switch off; LED bulb failure.Check power connection; Turn power switch on; Contact support for bulb replacement.
Imej kabur atau tidak fokusIncorrect focus knob used; Slide upside down; Objective lens dirty; Condenser/diaphragm not adjusted.Use fine focus for precise adjustment; Ensure slide cover slip is up; Clean objective lens; Adjust condenser and iris diaphragm.
Padang gelap viewIris diaphragm closed too much; Condenser too low; Light intensity too low.Open iris diaphragm; Raise condenser; Increase LED brightness.
Dust or spots in field of viewDust on eyepiece, objective, or slide.Clean eyepieces and objectives with lens paper; Clean slide.

7. Spesifikasi

CiriPerincian
kepalaSiedentopf Binocular, 30-degree inclined, 360-degree rotatable
Cermin mataWF 10x (Widefield)
Objektif4X, 10x, 40xS (spring), 100xS (spring, oil) DIN Achromatic
Julat Pembesaran40X - 1000X
StageDouble-layer Mechanical Stage with 1.0mm divisions
PencahayaanTransmitted (bottom) Brightfield LED
Pemeluwap1.25 NA Abbe with Iris Diaphragm
kuasa110V / 220V (Dwi Voltantage)
Dimensi (L x W x H)11 x 7 x 13.75 inci (27.94 x 17.78 x 34.92 cm)
Berat Barang9.25 paun (4.2 kg)
bahanEnamel-coated cast-steel body, Glass optics

8. Waranti dan Sokongan

For warranty information and technical support, please contact the manufacturer, United Scope LLC., directly. Details regarding product warranty periods and service procedures are typically provided with your purchase documentation or can be found on the official AmScope webtapak.

Anda boleh melawat AmScope Store on Amazon for more information or to find contact details for support.

© 2024 AmScope. All rights reserved. Information subject to change without notice.