1. Pengenalan

The Fluke LVD2 is a versatile non-contact AC voltage detector combined with an LED flashlight, designed for commercial and industrial applications. This pen-style device offers dual sensitivity, indicating proximity to an AC voltage source with a blue light and direct presence at the source with a red light. It is rated to CAT IV 600 V, ensuring high safety standards for electrical testing.

2. Maklumat Keselamatan

Always prioritize safety when working with electrical systems. This device is designed to assist in identifying live circuits, but it should not be the sole method for verifying de-energized circuits. Always follow local safety codes and procedures. Ensure the device is functioning correctly before each use by testing it on a known live circuit.

  • CAT IV 600 V Rating: This rating indicates the device is suitable for measurements at the source of the low-voltage pemasangan, seperti meter elektrik dan peranti perlindungan arus lebih utama.
  • Voltage Julat: Mengesan AC voltage from 90 V to 600 V. Do not use outside this specified range.
  • Pemeriksaan: Before each use, inspect the tester for any damage. Do not use if it appears damaged.
  • Keadaan Persekitaran: Operating temperature range is 0 to 50 degrees Celsius. Avoid using in wet or excessively humid conditions unless specifically rated for such environments.

3. Ciri-ciri Produk

  • Dual sensitivity for voltagpengesanan e.
  • Integrated LED light with a 100,000-hour life.
  • Mengesan AC voltage daripada 90 V hingga 600 V.
  • Rated to CAT IV 600 V for enhanced safety.
  • Blue light indicates proximity to an AC voltage source (1 to 5 inches / 2.54 cm to 12.7 cm).
  • Red light indicates direct presence at the AC voltage sumber.
  • Compact pen-style design for easy portability.

4. Persediaan

4.1 Pemasangan Bateri

The Fluke LVD2 requires one AAA battery for operation. While some units may include a battery, it is recommended to have a fresh battery on hand for optimal performance.

  1. Twist and pull off the cap at the end of the tester to access the battery compartment.
  2. Masukkan satu bateri AAA, pastikan kekutuban (+/-) betul seperti yang ditunjukkan di dalam petak.
  3. Replace the cap by twisting it back into place until secure.

After installing the battery, press the power button to ensure the LED flashlight turns on, indicating proper battery installation and functionality.

5. Arahan Operasi

5.1 Menghidupkan/Mematikan

To power on the Fluke LVD2 and activate the LED flashlight, press the power button located on the body of the tester. Press the button again to turn off the device and the flashlight.

5.2 Bukan Kenalan Voltage Pengesanan

The LVD2 utilizes dual sensitivity to indicate the presence and proximity of AC voltage:

  • Blue Light Indication: When the tip of the tester is brought within 1 to 5 inches (2.54 cm to 12.7 cm) of an AC voltage source, the tip will illuminate blue. This indicates proximity to a live circuit.
  • Red Light Indication: As the tester's tip comes into direct contact or very close proximity with the AC voltage source, the tip will illuminate red. This signifies that you are directly at the source of the live voltage.

Always observe both light indications for accurate assessment. The integrated LED flashlight aids in illuminating dark work areas, enhancing visibility during testing.

Vol. Bukan Kenalan Fluke LVD2tage Penguji

Figure 1: The Fluke LVD2 Non-Contact Voltage Tester, showing its pen-style design and the clear tip for light indication.

Fluke LVD2 with blue light indicating voltage proximity

Figure 2: The Fluke LVD2 in use, demonstrating the blue light indication when detecting AC voltage dari jauh.

6. Penyelenggaraan

6.1 Pembersihan

To clean the exterior of the tester, use a soft, damp kain. Jangan gunakan pembersih atau pelarut yang kasar. Pastikan peranti kering sepenuhnya sebelum penyimpanan atau penggunaan seterusnya.

6.2 Penggantian Bateri

When the LED flashlight dims or the voltage detection becomes unreliable, it is time to replace the AAA battery. Follow the battery installation steps in Section 4.1. Always dispose of used batteries responsibly according to local regulations.

7. Penyelesaian masalah

MasalahKemungkinan PuncaPenyelesaian
Tester does not turn on.Bateri mati atau tidak dipasang dengan betul.Gantikan bateri, pastikan polariti yang betul.
No light indication when near live circuit.Battery low or dead; circuit voltage outside detection range (90-600V AC); device malfunction.Replace battery. Verify circuit voltage is within range. If problem persists, contact Fluke support.
Inconsistent or false readings.Strong electromagnetic interference; device too far from source; low battery.Move away from strong interference sources. Ensure close proximity to the conductor. Replace battery.

8. Spesifikasi

SpesifikasiNilai
ModelLVD2/CT
Julat Pengesanan90 V hingga 600 V AC
Penilaian KeselamatanCAT IV 600V
Sumber CahayaUltra-Bright White LED (100,000 hr life)
Penunjuk PengesananBlue (proximity), Red (at source)
Sumber Kuasa1 x Bateri AAA
Suhu Operasi0 hingga 50 °C (32 hingga 122 °F)
Dimensi (L x W x H)Approximately 20 x 20 x 2 inches (as per product data, likely package dimensions)
Berat Barang1.06 auns

9. Waranti dan Sokongan

The Fluke LVD2 Non-Contact Voltage Tester typically comes with a Waranti 2 tahun from the date of purchase, as indicated by customer reviews. For detailed warranty terms, technical support, or service inquiries, please visit the official Fluke webtapak atau hubungi bahagian perkhidmatan pelanggan mereka. Simpan bukti pembelian anda untuk tuntutan waranti.

Official Fluke Webtapak: www.fluke.com

© 2024 Fluke Corporation. Hak cipta terpelihara.

This manual is for informational purposes only. Fluke reserves the right to change specifications without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.