AmScope D120A-MS

AmScope D120A-MS Dwi-View Manual Arahan Mikroskop Monokular Kompaun

Model: D120A-MS

1. Pengenalan

The AmScope D120A-MS is a dual-view compound monocular microscope designed for high magnification observation in biological and educational applications. It features a versatile viewing head, multiple objective lenses, Brightfield illumination, and a mechanical stage for precise specimen manipulation. This manual provides essential information for the proper setup, operation, and maintenance of your microscope.

2. Garis Panduan Keselamatan

  • Always handle the microscope with care. Avoid sudden movements or impacts.
  • Ensure the microscope is placed on a stable, level surface to prevent tipping.
  • Connect the power cord to a grounded electrical outlet of the correct voltage (110V).
  • Do not touch optical surfaces with bare hands. Use lens paper or a soft, lint-free cloth for cleaning.
  • Unplug the microscope from the power source before cleaning or performing any maintenance.
  • Jauhkan mikroskop daripada cahaya matahari langsung, suhu tinggi, habuk dan bahan kimia yang menghakis.
  • Supervise children or inexperienced users to ensure safe operation.

3. Kandungan Pakej

Buka pek semua komponen dengan berhati-hati dan sahkan bahawa item berikut disertakan:

  • AmScope D120A-MS microscope with mechanical stage
  • WF10x eyepiece
  • WF16x eyepiece
  • 4x DIN achromatic objective
  • 10x DIN achromatic objective
  • 40xS DIN achromatic objective (spring-loaded)
  • 100xS (oil) DIN achromatic objective (spring-loaded)
  • (2) Color filters
  • Mentol ganti
  • Penutup habuk
  • Manual arahan (dokumen ini)

4. Pengenalan Komponen

Familiarize yourself with the main parts of your AmScope D120A-MS microscope:

AmScope D120A-MS Dwi-View Mikroskop Monokular Kompaun

Rajah 4.1: Berakhirview of the AmScope D120A-MS microscope. This image displays the complete microscope assembly, including the base, stage, objective lenses, and dual-view monocular head.

  • Kanta Mata (Okular): Ke mana anda melihat view the specimen. The D120A-MS includes WF10x and WF16x eyepieces.
  • Monokular ViewKetua: The upper part of the microscope containing the eyepiece tube. This model features a dual-view head with a fixed 45-degree inclined tube and a vertical port.
  • Hidung Berputar: Holds the objective lenses and allows for easy switching between magnifications.
  • Kanta Objektif: The primary magnification components (4x, 10x, 40xS, 100xS oil).
  • Mekanikal Stage: A platform where the specimen slide is placed, with controls for precise X-Y movement.
  • Stage Klip: Secure the specimen slide on the mechanical stage.
  • Tombol Fokus Kasar: Large knob for rapid focusing adjustments.
  • Tombol Fokus Halus: Small knob for precise focusing adjustments.
  • Illuminator (Light Source): Terletak di bawah stage, provides light for viewing. This model uses variable-intensity tungsten illumination.
  • Abbe Condenser: Terletak di bawah stage, focuses light onto the specimen. Features a 1.25 NA and an iris diaphragm.
  • Diafragma Iris: Controls the amount of light passing through the specimen.
  • Pangkalan: The stable bottom support of the microscope.

5. Pemasangan dan Persediaan

Follow these steps to set up your microscope for initial use:

  1. Membongkar: Carefully remove the microscope and all accessories from the packaging. Retain the original packaging for future transport or storage.
  2. penempatan: Place the microscope on a sturdy, level surface, away from vibrations and direct sunlight.
  3. Pemasangan Kanta Mata: Insert the desired eyepiece (WF10x or WF16x) into the inclined eyepiece tube of the monocular head. Gently twist to secure it.
  4. Pemasangan Objektif: The objective lenses are typically pre-installed. If not, carefully screw each objective into the revolving nosepiece in increasing order of magnification (4x, 10x, 40xS, 100xS). Ensure they are finger-tight.
  5. Close-up of AmScope D120A-MS objective lenses

    Rajah 5.1: jarak dekat view of the objective lenses mounted on the revolving nosepiece. This image shows the 4x, 10x, 40xS, and 100xS (oil) objectives in position.

  6. Sambungan Kuasa: Connect the power cord to the microscope's power input and then to a standard 110V electrical outlet.
  7. Penutup habuk: When not in use, cover the microscope with the provided dust cover to protect it from dust and debris.

6. Operasi Asas

This section outlines the fundamental steps for observing specimens with your microscope.

  1. Hidupkan kuasa: Flip the power switch located on the base of the microscope. The illuminator should light up.
  2. Laraskan Pencahayaan: Use the variable intensity control knob to set the desired brightness. Adjust the iris diaphragm on the Abbe condenser to optimize contrast and resolution for your specimen.
  3. Letakkan Spesimen: Rotate the revolving nosepiece to select the lowest power objective (4x). Lower the mechanical stage using the coarse focus knob. Place a prepared specimen slide onto the mechanical stage dan selamatkannya dengan stage klip.
  4. Position Specimen: Gunakan XY stage control knobs to move the slide until the area of interest is centered under the objective lens.
  5. Memfokuskan:
    • While looking through the eyepiece, slowly raise the stage menggunakan coarse focus knob until the specimen comes into rough focus.
    • Gunakan fine focus knob to achieve a sharp, clear image.
  6. Tukar Pembesaran: Once focused at low power, rotate the revolving nosepiece to switch to a higher power objective (e.g., 10x, 40xS). Due to the parfocal design, only minor adjustments with the fine focus knob should be needed to bring the image back into sharp focus.
  7. Using the 100xS Oil Immersion Objective:
    • After focusing with the 40xS objective, rotate the nosepiece halfway between the 40xS and 100xS objectives.
    • Place a small drop of immersion oil directly onto the center of the specimen slide where the light passes through.
    • Carefully rotate the 100xS objective into the oil drop until it clicks into place. The objective should be immersed in the oil.
    • Gunakan hanya fine focus knob to bring the image into sharp focus. Do not use the coarse focus knob with the 100xS objective.
    • After use, clean the 100xS objective and the slide immediately with lens paper moistened with lens cleaning solution to remove all immersion oil.
  8. Dwi-View Kefungsian: The vertical port on the monocular head can accept a second eyepiece for simultaneous viewing by another person or a camera mount for digital image capture (eyepiece and camera sold separately). Dioptric adjustment on the upright tube accommodates individual eye-strength differences.
  9. AmScope D120A-MS microscope connected to a laptop for digital imaging

    Rajah 6.1: The AmScope D120A-MS microscope demonstrating its digital image capture capability by connecting to a laptop. This setup utilizes the vertical port for a camera attachment.

7. Penyelenggaraan dan Penjagaan

Penyelenggaraan yang betul memastikan jangka hayat dan prestasi optimum mikroskop anda.

  • Kanta Pembersihan: Use only specialized lens paper and lens cleaning solution for optical surfaces. Gently wipe in a circular motion. Never use abrasive cloths or harsh chemicals.
  • Pembersihan Am: Lap badan mikroskop dengan kain lembut,amp cloth. Avoid getting moisture into electrical components.
  • Storan: Always cover the microscope with the dust cover when not in use. Store it in a dry, dust-free environment.
  • Penggantian mentol: If the illuminator bulb burns out, unplug the microscope. Refer to the base of the microscope for access to the bulb compartment. Carefully replace the old bulb with the provided spare bulb, ensuring not to touch the glass part of the new bulb with bare hands.
  • Bahagian Mekanikal: Do not attempt to lubricate or disassemble any mechanical parts. If issues arise, contact customer support.

8. Penyelesaian masalah

Bahagian ini menangani isu biasa yang mungkin anda hadapi.

MasalahKemungkinan PuncaPenyelesaian
Tiada pencahayaanPower cord disconnected, power switch off, bulb burnt outCheck power connection, turn on switch, replace bulb
Imej kabur atau tidak fokusIncorrect focus adjustment, objective not fully engaged, dirty lensAdjust coarse/fine focus, rotate nosepiece until objective clicks, clean lenses
Padang gelap viewIris diaphragm closed, illuminator too dim, condenser too lowOpen iris diaphragm, increase illuminator brightness, adjust condenser height
Dust or spots in viewDust on eyepiece, objective, or slideClean eyepiece, objective, or slide with lens paper
Cannot focus at 100xNo immersion oil, air bubbles in oil, coarse focus usedApply immersion oil, remove air bubbles, use only fine focus

9. Spesifikasi Teknikal

Detailed specifications for the AmScope D120A-MS microscope:

  • Ketua: Compound dual-view monocular, 45-degree inclined, 360-degree rotatable
  • kanta mata: WF10x, WF16x (with pointer)
  • Objektif: 4X, 10x, 40xS (spring), 100xS (oil, spring) DIN achromatic
  • Julat Pembesaran: 40X - 1600X
  • Stage: Mekanikal stage with X-Y axis movement, stage berhenti
  • Konfigurasi Pencahayaan: Transmitted (lower)
  • Pemeluwap: Abbe, 1.25 NA
  • Diafragma: Diafragma iris
  • Sumber Cahaya: Tungsten (incandescent), variable intensity
  • Jenis Pencahayaan: Brightfield
  • Kuasa: 110V
  • Bahan: Metal, tungsten
  • Dimensi (H x W x D): 15 x 7.5 x 5.125 inci (anggaran)
  • Berat: 10 paun

10. Waranti dan Sokongan Pelanggan

For warranty information, technical assistance, or to purchase replacement parts, please contact AmScope customer support. Refer to the AmScope weblaman web atau dokumentasi pembelian anda untuk butiran hubungan semasa.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.